Category:Observing Preparation: Difference between revisions
Line 51: | Line 51: | ||
==== Polarization Calibrator Catalog ==== | ==== Polarization Calibrator Catalog ==== | ||
The following sources are known to be | The following sources are known to be useable for polarization calibration. These consist of a few "pol standard" sources with known stable polarization (for Q/U angle calibration), plus a number of bright sources with variable flux density and polarization (monitored by EVLA). There are also a few "bright, low pol" sources available as leakage calibrators (but the can have measureable polarization at high frequencies). | ||
WARNING: Be sure to use the EVLA OPT Source catalog to get the standard J2000 positions and see the fluxes. | |||
WARNING: | |||
{| border="1" align="center" | {| border="1" align="center" | ||
|+ '''Table 1: Verified unpolarized and polarized calibrator sources''' | |+ '''Table 1: Verified unpolarized and polarized calibrator sources''' | ||
!Source | !Source | ||
! | !Other name | ||
!Comments | !Comments | ||
|- | |- | ||
| J0137+3309 || | | J0137+3309 || B0134+329 (3C48) || pol standard (<6cm) | ||
|- | |- | ||
| J0319+4130 || | | J0319+4130 || B0316+413 (3C84) || low pol, bright, flat spectrum | ||
|- | |- | ||
| J0521+1638 || | | J0521+1638 || B0518+165 (3C138) || pol standard | ||
|- | |- | ||
| J0713+4349 || | | J0713+4349 || B0710+439 || CSO, monitored | ||
|- | |- | ||
| J1331+3030 || | | J1331+3030 || B1328+307 (3C286) || pol standard | ||
|- | |- | ||
| J1407+2827 || | | J1407+2827 || B1404+286 (OQ208) || low pol, steep spectrum | ||
|- | |- | ||
| J2355+4950 || | | J2355+4950 || B2352+495 || CSO, monitored | ||
|- | |- | ||
|} | |} | ||
Comments: at least one "pol standard" should be included for angle calibration | Comments: | ||
* at least one "pol standard" should be included for angle calibration | |||
* "monitored" sources can be found at http://www.vla.nrao.edu/astro/calib/polar/ | |||
* "steep spectrum" sources are likely weak at high frequencies | |||
The following sources are known to be CSO (Compact Symmetric Objects) and are characteristically unpolarized. They can be used over a range of frequencies (Gugliucci, N.E. et al. 2007, ApJ 661, 78) as "low pol" leakage calibrators. CSOs tend to be on the weak side and should be used with care at higher frequencies. | |||
WARNING: the positions given below are B1950, use the Source names in the EVLA OPT to get the J2000 positions. | |||
{| border="1" align="center" | {| border="1" align="center" | ||
Line 113: | Line 116: | ||
|} | |} | ||
Comments: northern CSO sources from Gugliucci et al. study (see above). | Comments: | ||
* northern CSO sources from Gugliucci et al. study (see above). | |||
==== Monitoring Observations ==== | ==== Monitoring Observations ==== |
Revision as of 23:24, 16 November 2010
Polarization Calibration
Current OSS Guidelines
For projects requiring imaging in Stokes Q and U, the instrumental polarization should be determined through observations of a bright calibrator source spread over a range in parallactic angle. In nearly all cases, the phase calibrator chosen can double as a polarization calibrator provided it is at a declination where it moves through enough parallactic angle during the observation (roughly Dec 15deg to 50deg for a few hour track). The minimum condition that will enable accurate polarization calibration from a polarized source (in particular with unknown polarization) is three observations of a bright source spanning at least 60 degrees in parallactic angle (if possible schedule four scans in case one is lost). If a bright unpolarized unresolved source is available (and known to have very low polarization) then a single scan will suffice to determine the leakage terms. The accuracy of polarization calibration is generally better than 0.5% for objects small compared to the antenna beam size. At least one observation of 3C286 or 3C138 is required to fix the absolute position angle of polarized emission. 3C48 also can be used to fix the position angle at wavelengths of 6 cm or shorter. The results of a careful monitoring program of these and other polarization calibrators can be found at http://www.vla.nrao.edu/astro/calib/polar/.
High sensitivity linear polarization imaging may be limited by time dependent instrumental polarization, which can add low levels of spurious polarization near features seen in total intensity and can scatter flux throughout the polarization image, potentially limiting the dynamic range. Preliminary investigation of the EVLA’s new polarizers indicates that these are extremely stable over the duration of any single observation, strongly suggesting that high quality polarimetry over the full bandwidth will be possible.
The accuracy of wide field linear polarization imaging will be limited, likely at the level of a few percent at the antenna half-power width, by angular variations in the antenna polarization response. Algorithms to enable removable of this angle-dependent polarization are being tested, and observations to determine the antenna polarizations have begun. Circular polarization measurements will be limited by the beam squint, due to the offset secondary focus feeds, which separates the RCP and LCP beams by a few percent of the FWHM. The same algorithms noted above to correct for antenna-induced linear polarization can be applied to correct for the circular beam squint. Measurement of the beam squints, and testing of the algorithms, is ongoing.
Ionospheric Faraday rotation of the astronomical signal is always notable at 20 cm. The typical daily maximum rotation measure under quiet solar conditions is 1 or 2 radians/m2, so the ionospherically-induced rotation of the plane of polarization at these bands is not excessive – 5 degrees at 20 cm. However, under active conditions, this rotation can be many times larger, sufficiently large that polarimetry is impossible at 20 cm with corrrection for this effect. The AIPS program TECOR has been shown to be quite effective in removing large-scale ionospherically induced Faraday Rotation. It uses currently-available data in IONEX format. Please consult the TECOR help file for detailed information. In addition, the interim EVLA receivers generally have poor polarization performance outside the frequency range previously covered by the VLA (e.g., outside the 4.5–5.0 GHz frequency range for C band, and outside 1.3–1.7 GHz for L-band), and the wider frequency bands of these interim receivers may be useful only for total intensity measurements.
Revised Guidelines
Observing Recommendations
There are several strategies for deriving the instrumental polarization:
- Single scan observation of a zero polarization source (see catalog below)
- Several scans (minimum of 3 over 60 degrees of parallactic angle) of an unknown polarization source
- Two scans of a source of known polarization (see catalog below)
Low Frequency Considerations
- Ionosphere monitoring
Global Ionospheric TEC maps are available via: http://iono.jpl.nasa.gov/latest_rti_global.html
- Solar activity monitoring
Solar activity and general space weather can be reviewed at the NOAA site: http://www.swpc.noaa.gov/today.html
The site provides solar activity forecasts and geophysical (geomagnetic field) activity forecasts along with GOES X-ray flux values.
High Frequency Considerations
- Source list restrictions
- Need longer observations
Time stability
Current results (by band)
Frequency stability
Current results (by band)
Polarization Calibrator Catalog
The following sources are known to be useable for polarization calibration. These consist of a few "pol standard" sources with known stable polarization (for Q/U angle calibration), plus a number of bright sources with variable flux density and polarization (monitored by EVLA). There are also a few "bright, low pol" sources available as leakage calibrators (but the can have measureable polarization at high frequencies). WARNING: Be sure to use the EVLA OPT Source catalog to get the standard J2000 positions and see the fluxes.
Source | Other name | Comments |
---|---|---|
J0137+3309 | B0134+329 (3C48) | pol standard (<6cm) |
J0319+4130 | B0316+413 (3C84) | low pol, bright, flat spectrum |
J0521+1638 | B0518+165 (3C138) | pol standard |
J0713+4349 | B0710+439 | CSO, monitored |
J1331+3030 | B1328+307 (3C286) | pol standard |
J1407+2827 | B1404+286 (OQ208) | low pol, steep spectrum |
J2355+4950 | B2352+495 | CSO, monitored |
Comments:
- at least one "pol standard" should be included for angle calibration
- "monitored" sources can be found at http://www.vla.nrao.edu/astro/calib/polar/
- "steep spectrum" sources are likely weak at high frequencies
The following sources are known to be CSO (Compact Symmetric Objects) and are characteristically unpolarized. They can be used over a range of frequencies (Gugliucci, N.E. et al. 2007, ApJ 661, 78) as "low pol" leakage calibrators. CSOs tend to be on the weak side and should be used with care at higher frequencies. WARNING: the positions given below are B1950, use the Source names in the EVLA OPT to get the J2000 positions.
Source | RA (1950) | DEC (1950) | B1950 Name' | Comments |
---|---|---|---|---|
J0029+3456 | 00 26 34.8386 | 34 39 57.586 | 0026+346 | CSO |
J0111+3906 | 01 08 47.2595 | 38 50 32.691 | 0108+388 | CSO |
J0410+7656 | 04 03 58.60 | 76 48 54.0 | 0404+768 | CSO |
J1035+5628 | 10 31 55.9562 | 56 44 18.284 | 1031+567 | CSO |
J1148+5924 | 11 46 10.4160 | 59 41 36.834 | 1146+596 | CSO |
J1400+6210 | 13 58 58.310 | 62 25 08.40 | 1358+624 | CSO |
J1815+6127 | 18 15 05.4851 | 61 26 04.496 | 1815+614 | CSO |
J1823+7938 | 18 26 43.2676 | 79 36 59.943 | 1826+796 | CSO |
J1944+5448 | 19 43 22.6729 | 54 40 47.955 | 1943+546 | CSO |
J1945+7055 | 19 46 12.0492 | 70 48 21.397 | 1946+708 | CSO |
J2022+6136 | 20 21 13.3005 | 61 27 18.157 | 2021+614 | CSO |
Comments:
- northern CSO sources from Gugliucci et al. study (see above).
Monitoring Observations
Description and scope.
List of observation dates and results.
Post-processing Guidelines
Perhaps just a pointer to the CASA guides page for the relevant section.
This category currently contains no pages or media.